BHNXK - RUST TRANSFORMER (BULK) 763
- MSDS: BHNXK
- Manufacturer: AW CHESTERTON COMPANY
- Product Name: RUST TRANSFORMER (BULK) 763
- National Stock Number: 8020-00N010671
Product Identification
Product ID:RUST TRANSFORMER (BULK) 763
MSDS Date:01/01/1987
FSC:8020
NIIN:00N010671
MSDS Number: BHNXK
Responsible Party
STONEHAM, MA 02180
Emergency Phone: 617-438-7000 DAY;617-438-7013 NIGHT
Info Phone: 617-438-7000
Cage: HO586
Contractor
Telephone: 781-438-7000/800-535-5053
Cage: 71431
Ingredients
ETHYLENE GLYCOL (SARA III)
CAS: 107-21-1
RTECS: KW2975000
Fraction By Weight: 15-25%
OSHA PEL C 50 PPM
ACGIH TLV: C 50 PPM,VAPOR; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ISOPROPYL ALCOHOL (SARA III)
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 10-20%
OSHA PEL 400 PPM/500 STEL
ACGIH TLV: 400 PPM/500STEL;9192
BARIUM (SARA III)
CAS: 7440-39-3
RTECS: CQ8370000
Fraction By Weight: 1-5%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG/M3; 9192
Hazards
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:REPEATED OVEREXPOSURE TO ETHYLENE
GLYCOL CAN CAUSE KIDNEY AND LIVER EFFECTS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES:SEVERE IRRITANT.MAY CAUSE
BURNS.SKIN:PROLONGED OR REPEATED CONTACT MAY DEFAT THE SKIN AND
CAUSE IRRITATION.INGESTION:N/K .INHALATION:INHALATION OF VAPOR IN
EXCESS OF PEL/TLV MAY RESULT IN DIZZINESS,HEADACHE AND OTHER CNS
EFFECTS.
Medical Cond Aggravated by Exposure:N/K
First Aid
First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MIN.CONTACT MD.SKIN:WASH WITH SOAP & WATER.INGESTION:DO NOT INDUCE
VOMITING.IF CONSCIOUS,DILUTE WITH LARGE QUANTITIES OF WATER.CONTACT
MD IMMEDIA TELY.INHALATION:REMOVE TO FRESH AIR.IF NOT
BREATHING,ADMINISTER ARTIFICIAL RESPIRATION.CONTACT MD.
Fire Fighting
Flash Point Method:CC
Flash Point:31C,87F
Lower Limits:N/K
Extinguishing Media:DRY CHEMICAL,ALCOHOL TYPE FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .COOL EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:NONE.HAZARDOUS DECOMPOSITION
PRODUCTS:CARBON MONOXIDE AND OTHER TOXIC FUMES.
Accidental Release
Spill Release Procedures:EVACUATE AREA.PROVIDE ADEQUATE
VENTILATION.CONTAIN SPILL TO SMALL AREA.FLUSH AWAY FROM IGNITION
SOURCES WITH WATER.PICK UP WITH ABSORBENT MATERIAL AND PLACE IN A
SUITABLE CONTAINER FOR DISPOSAL.KEEP O UT OF SEWERS,STREAMS AND
WATERWAYS.
Neutralizing Agent:N/K
Handling
Handling and Storage Precautions:CONTAINERS MUST BE GROUNDED AND BONDED
DURING POURING.
Other Precautions:WASH BEFORE EATING,DRINKING OR SMOKING.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW TLV .
Protective Gloves:CHEMICAL RESISTANT.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE
Work Hygienic Practices:WASH BEFORE EATING,DRINKING OR SMOKING.
Supplemental Safety and Health
N/K
Chemical Properties
Boiling Pt:B.P. Text:100C,212F
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:N/K
Vapor Density:>1 (AIR=1)
Spec Gravity:1.07 (WATER=1)
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:N/K
Appearance and Odor:LIQUID
Percent Volatiles by Volume:67
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS LIKE LIQUID CHLORINE AND CONCENTRATED OXYGEN.
Stability Condition to Avoid:OPEN FLAMES AND RED HOT SURFACES.
Hazardous Decomposition Products:CARBON MONOXIDE AND OTHER TOXIC FUMES.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .INCINERATE OR BURY ABSORBED
MATERIAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.